MIL-M-46861B (MI)
e. Remove the specimens and place in a desiccator until cooled to ambient room temperature.
f. Reweigh the specimens to the nearest 0.01 gram. g. Calculate the volatile content using the formula:
WO - W1
CV (%) = x 100
WO
Where:
CV (%) = Volatile content percent
WO = Original specimen weight
W1 = Devolatilized specimen weight
h. Report the individual and average of five specimens. The volatiles content shall be as specified in 3.3.1.
4.8.9 Resin content. The resin content shall be determined in accordance with ASTM D 613. Specimens shall be those devolatilized specimens used in the volatiles determination of 4.8.8. The resin content shall be as specified in 3.3.1.
4.8.10 Gel time. The gel time shall be determined as follows:
a. Specimens approximately 2 x 2 inches shall be selected from random areas in the sample.
b. The specimen shall be placed resin side down on a hot plate preheated from 149 to 165°C.
c. After three to five seconds, remove the sample, leaving a small amount of resin on the surface of the hot plate.
d. Start the stop watch.
e. Probe the resin until it will no longer form strings when the probe is removed.
f. Stop the watch and record the gel time.