MIL-PRF-87260B(USAF)
and the conductive material (6 inches x 3 inches x 1 inch). The comparison cells shall have
blue polyether foam of similar porosity substituted in place of the conductive material. The
metals shall conform to the following specifications:
a.
305 stainless steel per SAE AMS-QQ-P-35 or ASTM A967.
b.
Bare 7075 aluminum per SAE AMS-QQ-A-250 or ASTM B209.
c.
Bare 2024 aluminum per SAE AMS-QQ-A-250 or ASTM B209.
The test cell set-up and bonding schematic is shown in FIGURE 5.
Cell #1
Cell #2
Baffle
Baffle
Material
Material
7075 Alumi
305 Aluminum
2074 Alumi
num
Steel
num
Plates
Plates
Plates
Test Cell
Humidity Cabinet
Electrometer
FIGURE 5. Electromechanical test set-up.
33
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.